RHUB TM-510 Especificaciones Pagina 250

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 353
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 249
9-6
TM 9-2350-311-34-1
9-1 PERSONNEL AIRDUCT VENTILATING FAN
— CONTINUED
C. Assembly — Continued
5
6
7
8
9
10
11
12
13
Install two electrical brushes (25) and two screws (24).
Install end cover (27) and two screws (26).
Feed electrical leads (11) through grommet hole (22) and install motor assembly (23). Install new grommet
(21).
Install four flat washers (19), four screws (18), and new Iockwire (17) to front of housing (20).
Install noise filter (8), four flat washers (15), four screws (14), ground wire (16), and new Iockwire (13).
Rewire noise filter (8). See schematic for complete instructions.
Connect four electrical leads (11) to noise filter terminals (12) and install four new Iockwashers (10) and four
nuts (9).
Install noise filter cover (7), two new Iockwashers (6), and two nuts (5) to noise filter (8).
Install shaft key (4), impeller (3), two washers (2), and nut (1).
Vista de pagina 249
1 2 ... 245 246 247 248 249 250 251 252 253 254 255 ... 352 353

Comentarios a estos manuales

Sin comentarios