TM 9-2350-311-34-1
1 Assemble electrical leads as required (TM 9-2350-311-20-1).
NOTE
Refer to electrical wiring diagram for installation of leads.
2 Solder lead (56) to capacitor board (59) (TB SIG 222).
3 Solder three leads (57) to capacitor board (55) (TB SIG 222).
Acetone solvent is toxic and flammable. Use only in well-ventilated area. Do not
breathe vapors. Do not use near open flame or excesive heat. Failure to heed warning
could cause serious injury or even death.
NOTE
Step 4 applies only if capacitor boards (55 and 59) are used.
4 Clean two capacitor boards (55 and 59) with acetone solvent to remove remains of pressure-sensitive tape.
5 Install two strips of pressure-sensitive tape to each capacitor board (55 and 59). Do not remove protective
coating.
6 Clean housing (56) mounting surface with acetone solvent.
7 Remove protective coating on tape and install two capacitor boards (55 and 59) as shown below.