TM 9-2350-311-34-1
3
Remove four nuts (9), four Iockwashers (10), and four electrical leads (11 ) from noise filter terminals (1 2).
Discard Iockwashers.
4 Remove Iockwire (13), four screws (14), four flat washers (15), ground wire (16), and noise filter (8). Discard
Iockwire.
5 Remove Iockwire (17), four screws (18), and four flat washers (19) at front of housing (20). Discard Iockwire.
6 Remove grommet (21). Discard grommet.
7 Feed electrical leads (11 ) through grommet hole (22) and remove motor assembly (23).
8 Remove two screws (24) and two electrical brushes (25).
9 Remove two screws (26) and end cover (27).